BFPFH - OXYGEN, REFRIGERATED LIQUID
- MSDS: BFPFH
- Manufacturer: AIRCO
- Product Name: OXYGEN, REFRIGERATED LIQUID
- National Stock Number: 6830-00-781-8194
Product Identification
Product ID:OXYGEN, REFRIGERATED LIQUID
MSDS Date:08/09/1989
FSC:6830
NIIN:00-781-8194
MSDS Number: BFPFH
Responsible Party
MURRAY HILL, NJ 07974
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 201-464-8100
Cage: AIRCO
Contractor
Telephone: 800-424-9300(CHEMTREC)
Cage: 00741
Ingredients
OXYGEN REFRIGERATED LIQUID, 99.6000 TO 99.9970.
CAS: 7782-44-7
RTECS: RS2060000
Fraction By Weight: SEE ING
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HIGH CONCEN (>75%) CAUSE HYPEROXIA
WHICH IS CAPABLE OF LEADING TO DEATH & PNEUMONIA. CONCEN BETWEEN
25% & 75% PRESENT RISK OF INFLAMM OF ORGANIC MATTER IN BODY.
CONTACT W/LIQ OR COLD PIPING HAVING LIQ CAN CAUSE TISSUE
FREEZING/FROSTBITE.
Explanation of Carcinogenicity:PER MSDS CARCINOGENICITY IS NO FOR
NTP/IARC/OSHA.
Effects of Overexposure:INHAL:SYMPTOMS OF HYPEROXIA INCLUDE CRAMPS,
NAU, DIZZ, HYPOTHERMIA, AMBYLOPIA, RESP DIFFICULTIES, BRADYCARDIA,
FAINTING SPELLS & CONVULSIONS CAPABLE OF LEADING TO DEATH.CONTACT
W/CRYOGENIC LIQ CAN CAU SE TISSUE FREEZING OR FROSTBITE (CHANGEIN
COLOR OF SKIN TO GRAY OR WHITE FOLLOWED BY BLISTERING) ON DERM
CONTACT & EYE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MFG.
First Aid
First Aid:PROMPT MED ATTN IN ALL CASES.INHAL:REMOVE FROM EXPOSURE.STOP
BREATH GIVE ARTI RESUSC & OXYGEN.FURTHER TREATMENT SHOULD BE
SYMPTOMATIC & SUPPORTIVE.SKIN:FROSTBITE-FLUSH W/LUKEWARM WATER NOT
HOT.IF BLIS TERED OR DEEP TISSUE FREEZING SEE DR.EYE:DON'T USE
OINTMENT/OIL W/O MED ADVICE.FREEZING/BURNS DO NOT WASH W/HOT OR
TEPID WATER.REMOVE FROM CONTAMIN.OPEN EYELIDS FOR LIQ
EVAPORATION.PROTECT FROM LIGHT.
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:COPIOUS QUANTITIES OF WATER (OR SUITABLE
EXTINGUISHEING AGNET FOR COMBUSTLIBLE MTL) FOR FIRES W/OXYGEN AS
THE OXIDIZER.
Fire Fighting Procedures:IF POSSIBLE, STOP THE FLOW OF OXYGEN WHICH IS
SUPPORTING THE FIRE.
Unusual Fire/Explosion Hazard:VIGOROUSLY ACCELERATES COMBUSTION.
ELECTRICAL CLASSIFICATION:NON-HAZRDOUS.
Accidental Release
Spill Release Procedures:STATIONARY CUSTOMER SITE VESSELS SHOULD
OPERATE IN ACCORDANCE W/MFG'S & AIRCO'S INSTRUCTION. DO NOT ATTEMPT
TO REPAIR, ADJUST OR IN ANY OTHER WAY MODIFY OEPRATION OF VESSELS.
IF THERE'S A MALFUNCTION/ PROBLEM W/VESSEL CONTACT AIRCO IMMED.
Neutralizing Agent:NOT APPLICABLE.
Handling
Handling and Storage Precautions:USE ONLY IN WELL VENTI AREAS IAW MFG &
AIRCO/BOC INSTRUC.KEEP CYLN UPRIGHT.SPECIALIZED TRUCKS NEEDED FOR
MOVEMENT.EQPMT MUST BE CLEANED FOR OXY SERV.
Other Precautions:STORE FULL/EMPTY CYL AWAY FROM FLAMM MATL.CONSULT
COMPRESSED GAS ASSOC PAMPHLETS G-4,G-4.1,G-4.4,P-12,P-4.NEVER CARRY
COMPRESSED GAS CYLN/CNTNR W/CRYOGENIC LIQ IN ENCLOSED SPACE(CAR
TRUNK,VAN,STATION WAGON).NON-METALLIC GASKET:TEFLON,KELF.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MFG.
Ventilation:USE LOCAL EXHAUST TO PREVENT ACCUMULATION OF HIGH CONCEN
THAT INCREASE OXYGEN LEVEL IN AIR TO MORE THAN 25%.
Protective Gloves:LOOSE FITTING & INSULATED.
Eye Protection:SAFETY GOGGLES/GLASSES PLUS FACE SHIELD.
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER.
Work Hygienic Practices:CHECK W/SUPPLIER TO VERIFY OXYGEN COMPATABILITY
FOR SERVICE CONDITIONS.
Supplemental Safety and Health
1VOL OF LIQ OXY @ BOILING PT & ATM PRESS WILL VAPORIZE INTO APPROX
860VOL OF GASEOUS OXY @ 70F & 1ATM.LEAK CAN RESULT IN A
FIRE/EXPLO/ASPHYXIATION/TOXIC EXPOS.LIQ OXY CANNOT BE HANDLED IN
CARBON OR LO W ALLOY STEEL.ACCEPTABLE:18-8,18-10 STAINLESS
STEEL;CU,CU ALLOYS;NI,NI ALLOYS;BRASS BRONZE;SI
ALLOYS;MONEL;INCONEL;BE.
Chemical Properties
HCC:D1
Boiling Pt:B.P. Text:-297F,-183C
Melt/Freeze Pt:M.P/F.P Text:-362F,-219C
Vapor Pres:>CRIT TEMP
Spec Gravity:1.105
Solubility in Water:SLIGHTLY SOLUBLE
Appearance and Odor:A CLEAR PALE BLUE LIQUID, ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
ALL FLAMMABLE MATERIALS.
Stability Condition to Avoid:CONTACT WITH ALL FLAMMABLE MATERIALS. NO
SMOKING OR OPEN FLAMES SHOULD BE ALLOWED NEAR OXYGEN VESSELS.
Hazardous Decomposition Products:NONE SPECIFIED BY MFG.
Disposal
Waste Disposal Methods:NONE SPEICIFED BY MFG.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.